DESIGN AND EVALUATION OF A LORA
ARCHITECTURE FOR MULTIPARAMETER WATER

MONITORING WITH LIMITED CONNECTIVITY

DISEÑO Y EVALUACIÓN DE UNA ARQUITECTURA LORA
PARA MONITOREO MULTIPARAMÉTRICO DEL AGUA CON
CONECTIVIDAD LIMITADA

Rodrigo Jesús García de la Cruz

Tecnológico Nacional de México/Instituto Tecnológico de Villahermosa – Mexico

Victor Manuel Arias Peregrino

Tecnológico Nacional de México/Instituto Tecnológico de Villahermosa – Mexico

Clemente Hernández Arias

Tecnológico Nacional de México/Instituto Tecnológico de Villahermosa – Mexico

Hugo del Ángel Delgado

Tecnológico Nacional de México/Instituto Tecnológico de Villahermosa – Mexico
pág. 5074
DOI:
https://doi.org/10.37811/cl_rcm.v10i5.26351
D
esign and Evaluation of a LoRa Architecture for Multiparameter Water
Monitoring with Limited Connectivity

Rodrigo Jesús García de la Cruz
1
M24301259@villahermosa.tecnm.mx

https://orcid.org/0009-0002-7369-9708

Tecnológico Nacional de México/Instituto
Tecnológico de Villahermosa

Mexico

Victor Manuel Arias Peregrino

victor.ap@villahermosa.tecnm.mx

https://orcid.org/0000-0001-5925-4097

Tecnológico Nacional de México/Instituto
Tecnológico de Villahermosa

Mexico

Clemente Hernández Arias

clemente.hernandeza@villahermosa.tecnm.mx

https://orcid.org/0009-0001-7888-1966

Tecnológico Nacional de México/Instituto
Tecnológico de Villahermosa

Mexico

Hugo del Ángel Delgado

hugo.ad@villahermosa.tecnm.mx

https://orcid.org/0009-0002-1374-9478

Tecnológico Nacional de México/Instituto
Tecnológico de Villahermosa

Mexico

ABSTRACT

This article describes the design and functional evaluation of a point
-to-point LoRa architecture for
multiparameter water monitoring in environments with limited connectivity. An ESP32 node connected

to turbidity, temperature, and distance sensors transmi
ts independent encrypted messages to a Raspberry
Pi station, which processes the data in Python and stores them in MariaDB. The evaluation combined

software checks using synthetic data with a preliminary communication test at approximately 50 m,

followed b
y a temporary installation with an estimated separation of 35 m and physical obstacles, where
reception was restored after repositioning the antenna and sealing its outlet from the enclosure. The

console excerpt examined showed five complete cycles, equiva
lent to 15 readable messages, while
complementary checks reviewed the conversion of readings through calibration tables. The results

support the functional integration of acquisition, communication, and local processing under the

conditions examined and sh
ow that antenna placement affects link operation, although the scope of the
tests does not establish the maximum communication range, overall packet loss, or the metrological

accuracy of the sensors.

Keywords
: LoRa communication, multiparameter monitoring, water quality, embedded systems, local
processing

1 Autor Principal

Correspondencia:
M24301259@villahermosa.tecnm.mx
pág. 5075
Diseño y evaluación de una arquitectura LoRa para monitoreo
multiparamétrico del agua con conectividad limitada

RESUMEN

El presente artículo describe el diseño y la evaluación funcional de una arquitectura LoRa punto a punto
para el monitoreo multiparamétrico del agua en entornos con conectividad limitada, mediante un nodo
ESP32 conectado a sensores de turbidez, temperatura y distancia que transmite mensajes independientes
cifrados hacia una estación Raspberry Pi, encargada del procesamiento en Python y almacenamiento en
MariaDB. La evaluación combinó comprobaciones de software con datos sintéticos y una prueba
preliminar de comunicación a aproximadamente 50 m, seguida de una instalación temporal con
separación estimada de 35 m y obstáculos físicos, donde la recepción se restableció después de
modificar la posición de la antena y sellar su salida del gabinete. Como evidencia de funcionamiento,
el fragmento de consola examinado presentó cinco ciclos completos, equivalentes a 15 mensajes
legibles, mientras que las comprobaciones complementarias revisaron la conversión de lecturas
mediante tablas de calibración. Los resultados respaldan la integración funcional de adquisición,
comunicación y procesamiento local bajo las condiciones examinadas, y muestran que el montaje de la
antena interviene en la operación del enlace, aunque el alcance de las pruebas no permite determinar su
distancia máxima, la pérdida global de paquetes ni la precisión metrológica de los sensores.

Palabras clave:
comunicación LoRa, monitoreo multiparamétrico, calidad del agua, sistemas
embebidos, procesamiento local

Artículo recibido 20 agosto 2026

Aceptado para publicación: 20 setiembre 2026
pág. 5076
INTRODUCTION

Monitoring water
-related variables requires readings to be transferred from the measurement points to
a unit where they can be processed and accessed, making communication between devices necessary to

keep the information available. When sensors are locate
d in areas without access to a conventional
network, surrounded by tanks, structures, or vegetation, the design must account for both the separation

between the nodes and the physical conditions of the installation.

Several studies have addressed this need through sensors and monitoring platforms, including the work

of Forhad et al.
(2024), who integrated instrumentation, a programmable logic controller, and cloud
services to record water parameters at treatment facilities.
Their proposal connects data acquisition with
remote access and historical recording, although it requires an infrastructure different from that

considered in an architecture where processing and basic data access remain within a local station.

LoRa communication also has precedents in this field, including the system developed by Silva Torres

and Coello Hurtado (2020) to monitor temperature, turbidity, dissolved solids, and pH through

LoRaWAN, and the implementation by Jabbar et al.
(2024), which connects a sensor node to a gateway
and internet platforms to monitor water variables in rural areas.
These studies illustrate different ways
of organizing data acquisition and transmission, depending on the available resources and the services

that must
remain accessible during operation.
Pires and Gomes (2024) developed a system that transmits temperature, pH, conductivity, and turbidity

readings through LoRa to a station with local processing and Node
-RED visualization, with the option
of also sending the data to the cloud.
For river water level monitoring, Kabi, wa Maina, Mharakurwa,
and Mathenge (2023) used ultrasonic sensors and examined coverage through RSSI and SNR records

collected at different locations
. These studies provide a basis for considering how processing is
organized and h
ow communication conditions affect the proposed system.
To describe the proposal, LoRa must be distinguished from LoRaWAN: the former is the technology

used at the physical layer to transmit the radio signal, whereas the latter incorporates functions and

components for managing a device network (Baltuille, 2023
). The architecture developed in this study
establishes point
-to-point communication between the transmitting node and the receiving station,
without a LoRaWAN gateway or network server.
pág. 5077
The system integrates an ESP32 connected to three sensors and a Raspberry Pi that receives the

messages, applies the configured conversions, and manages the information through a local application,

so communication between the devices and basic access to t
he readings do not depend on internet
access. This arrangement addresses the need to connect a measurement point to a supervision area while

keeping processing and storage within the facility.

The objective of this article is therefore to describe the design and evaluate the functional integration

of a point
-to-point LoRa architecture for multiparameter water monitoring under limited-connectivity
conditions, focusing on message organization, lin
k installation, and the path followed by the readings
through processing and visualization. Calibration checks provide complementary evidence of data

conversion within the scope of the documented tests.

METHODOLOGY

Research approach and organization

The research followed a quantitative and applied approach directed toward the development of a

monitoring system consisting of hardware and software. Its evaluation drew on the count of documented

messages, processing checks, and readings used during senso
r adjustment, within a technological case
study that included development tests and a temporary installation in an operational water treatment

environment.

The units of observation comprised individual messages, transmission sequences, and executions of the

selected test cases, whose records were analyzed descriptively to determine whether the components

completed the expected data path. The results were inte
rpreted within the documented executions,
without extrapolating performance rates to extended periods or installations with different

characteristics.

Development was organized through an adaptation of Scrum to distribute the functions into work

increments, drawing on the iterative and incremental approach described by Schwaber and Sutherland

(2020). Verification followed the relationship between require
ments and tests established by the V-
Model, covering components, integration, application functions, and complete system operation. This

article primarily considers the cases associated with acquisition, LoRa reception, persistence,

calibration, and the co
mplete data path because of their direct relationship with the architecture being
pág. 5078
evaluated.

General system architecture

The architecture consists of an ESP32
-based acquisition node and a Raspberry Pi 5-based receiving
station, connected through Ra
-02 modules with SX1278 transceivers. The node gathers sensor readings
and transmits them sequentially, while the station interpr
ets the messages and performs local
processing, following the organization of software and hardware components shown in Figure 1.

Figur
e 1. Organization of the software and hardware components of the monitoring system
Note.
The diagram groups the system’s interface, local processing, and hardware components. Source: Own work.
A desktop application developed in Python manages reception, calibrations, and the visualization of

variables, while a local MariaDB database stores records for subsequent access through the system’s

available functions. The application also includes thres
hold alerts, report generation, and access control,
which support supervision of the readings without being the main focus of the communication analysis.

Communication between the nodes and basic data access do not require an internet connection. A

Telegram notification module, however, depends on an available connection at the receiving station

when that function is enabled, so independence from the intern
et refers to the local path of acquisition,
reception, processing, and access under the equipment’s operating conditions.

Acquisition and identification of variables

The TS
-300B sensor provides the analog signal associated with turbidity, from which the ESP32
calculates the average of ten analog
-to-digital converter readings and transmits the raw value under the
N2 identifier. The Raspberry Pi subsequently converts thi
s value using the active calibration table, so
the received message and the reading displayed by the application belong to different processing stages.
pág. 5079
Temperature is acquired with a DS18B20 through the OneWire interface and transmitted as N4,

provided that the program does not detect a sensor disconnection, in which case it omits the reading.

This variable was included as an additional parameter of the p
rototype, allowing its acquisition,
transmission, and presentation to be checked within the same architecture.

The JSN
-SR04T measures the distance to the water surface and transmits valid readings as N1, after
which the application relates the distance to a reference level and applies a level
-to-flow lookup table
to estimate the flow rate. This procedure depends on
the hydraulic relationship configured for the
installation, since the sensor measures distance and the flow estimate is calculated later from the points

recorded in the system.

Transmission organization

Each message contains a variable identifier and its value, placed in a 16
-byte block and encrypted using
AES
-128 before transmission through LoRa. The receiving station recovers the contents for
interpretation, and the functional encryption check verifies
that the original identifier and value can be
recovered without changes.

The expected sequence is N1, N2, and N4, with 200 ms pauses between transmissions and a base

waiting time of five seconds at the end of each cycle. Acquisition and transmission times must also be

included, so the programmed waiting time alone does not repr
esent the full interval between consecutive
readings of the same variable.

Messages are received independently, allowing the station to process the variables that arrive even when

a sequence remains incomplete. The implemented protocol does not include sequence numbers,

reception acknowledgments, or automatic retransmissions; bec
ause the program may also omit readings
that do not meet its validity conditions, a missing identifier in the console cannot, by itself, be attributed

to radio packet loss.

Local processing and storage

The receiving station identifies the sensor associated with each message and applies the corresponding

calibration through a table of input and output pairs, calculating intermediate values by linear

interpolation between consecutive points. For flow rate,
this conversion relates the calculated level to
the flow defined by the operational reference, whereas turbidity is processed from the raw value
pág. 5080
received from the node.

The application distinguishes the original reading from the converted value and retains a reference to

the calibration applied, making it possible to review which reading entered the system and which

adjustment was used before the result was displayed or r
ecorded. This arrangement preserves the
relationship between acquisition and processing, particularly when calibration points are modified.

During testing, the interface was updated after the received packets had been processed, while the

persistence service had a configured interval of 15 minutes. These functions therefore operate on

different schedules: the persistence interval describes the
storage configuration and does not measure
link latency or demonstrate that every packet is stored immediately after reception.

Testing procedure

Development checks included the construction, encryption, and recovery of synthetic messages using

the system identifiers, along with a review of interpolation using known level and flow
-rate inputs. The
acceptance criteria were to recover the original ide
ntifier and value without changes and reproduce the
expected interpolation outputs, keeping these software checks separate from observations of the

physical link.

Before the temporary installation, a preliminary communication check was performed at an

approximate separation of 50 m along a path that was not completely direct. Messages were observed

arriving at the receiver, allowing communication to be checked funct
ionally, although complete counts
and records of signal strength, signal
-to-noise ratio, and latency were not retained.
At the operational installation, the straight
-line separation was estimated at approximately 35 m using
a cartographic reference, with vegetation, structures, and differences in elevation between the nodes.

Two mounting conditions were examined: the antenn
a inside the fully closed enclosure and its
placement toward the cable opening, with the outlet sealed using silicone sealant.
Figure 2 presents the
equipment and installation evidence.
pág. 5081
Figur
e 2. Components and temporary installation of the monitoring system
Not
e. From left to right, the figure shows the components of the transmitting node, the enclosure installed next to the
measurement point, and the LoRa module connected to the receiving station. Source: Own work.

The functional acceptance criterion was to receive all three variables and complete the path defined by

test case CP
-SIS-001, from acquisition to access through the application. Reception was examined using
a console excerpt, and the subsequent functions w
ere reviewed through the corresponding integration
cases. Complementary checks examined two points used to adjust turbidity conversion with the DR/890

colorimeter and a visual comparison of the estimated flow rate against a level and flow
-rate scale.
Scope of the evaluation

The evaluation focused on the documented conditions of the prototype, as synchronized timestamps

and a continuous record of defined duration were not available to calculate end
-to-end latency or long-
term availability. RSSI, the received signal strength in
dicator, and SNR, the signal-to-noise ratio, were
not recorded either and therefore remained outside the quantitative results.

Personnel reviewed turbidity, flow rate, and the graphs during the session through exploratory,

qualitative assessments based on their interpretation of the readings. This review did not include a

structured survey or statistical measures of satisfaction o
r usability; the analysis is limited to technical
records and operational assessments and contains no personal data.

RESULTS

Functional behavior of the link

The preliminary check showed communication between the nodes before they were moved to the

operational environment and provided a basis for the temporary installation, although it does not

establish a reception rate or allow a quantitative comparison of pe
rformance at different distances. Table
1 summarizes the conditions of both checks and the mounting changes observed during installation.
pág. 5082
Tabl
e 1. Conditions and results of the LoRa link checks
Check
Approximate
separation
Physical condition Observed result
Preliminary
50 m Path not completely
direct

Functional message

reception, without a

complete count or

signal record

Installation
with internal
antenna

35 m
Closed enclosure
and obstructed path

No reception was
observed

Installation
with antenna
outlet

35 m

Antenna directed

toward the cable

opening, with the

outlet sealed using

silicone sealant

Reception was

restored;

configuration

accepted for the

functional test

Not
e. The 35 m separation is a straight-line cartographic estimate. The checks did not include RSSI, SNR, or latency
measurements, or a comparable procedure for calculating packet loss at different distances. Source: Own work.

Reception was restored after the antenna placement was changed. No messages had been observed at

the receiver while the antenna was confined inside the closed enclosure, whereas routing it through the

cable opening restored incoming data and allowed the fu
nctional test to continue. The opening was
sealed using silicone sealant, and the resulting configuration was accepted for the test while maintaining

protection around the outlet.

The difference shows that physical installation affected system operation, but the procedure did not

isolate the effects of orientation, contacts, component proximity, or antenna confinement. The result is

therefore associated with the change in mounting c
onfiguration, without attributing it to a particular
radio
-related cause that was not measured during the test.
Data reception and integration

Figure 3 shows the console excerpt used to review message identifiers and readability, in which

complete sequences of the expected variables can be distinguished. Table 2 brings together the counts

and complementary checks, separating reception records fro
m the synthetic inputs used during
development so that they are not interpreted as a single communication test.
pág. 5083
Figur
e 3. Excerpt showing the reception of N1, N2, and N4 messages at the Raspberry Pi station
Not
e. The identifiers correspond to distance, raw turbidity reading, and temperature, respectively. The excerpt shows received
messages and is not a complete record of the session’s transmissions. Source: Own work.

Tabl
e 2. Results of the reception and processing checks
Check
Source Quantity
examined

Documented
result

N1, N2, and N4

sequences
Console excerpt 5 cycles
Five complete

sequences,

equivalent to 15

readable messages

Message

construction,

encryption, and

recovery

Synthetic
development
inputs

300 messages

Identifier and

value recovered

without changes in

all 300 cases

Level and flow
-
rate interpolation

Synthetic
development
inputs

5 inputs

Five results

matching the

expected outputs

Persistence, CP-
BD-001

Documented
integration test
case

1 execution

Reading stored and

subsequently

retrieved

Complete data

path, CP
-SIS-001
Documented
system test case
1 execution
Complete

acquisition
-to-
visualization data

path

Not
e. The synthetic results correspond to software checks rather than field transmissions. Console messages do not allow an
overall reception rate to be calculated without the corresponding transmitter count. Source: Own work.

The value received under N2 is a raw reading from the analog
-to-digital converter, whose presence in
the console verifies message identification but should not be interpreted directly as a measurement in

NTU. Conversion takes place after reception and depe
nds on the active calibration, so the console
reading and the value displayed in the interface must be examined according to their respective

processing stages.
pág. 5084
Outside the selected excerpt, isolated omissions of a variable were observed without stopping the entire

service, as independent transmission allowed the received messages to continue being processed.

However, the absence of counters and sequence numbers p
revents overall packet loss from being
calculated or a distinction from being made in every case between a transmission omitted by the

program and a packet that was sent but did not reach the receiver.

The integration cases documented the storage and subsequent retrieval of a reading, as well as the

complete system data path, supporting the functional connection between reception, processing,

persistence, and visualization in the executions examined. The
console screenshot provides evidence of
the visible messages, while the database and application checks support the subsequent stages.

Processing and adjustment of readings

The synthetic checks examined the recovery of encrypted content and interpolation calculations using

known inputs, with results that describe software operation under the cases defined during development.

Their interpretation is limited to those procedures
, which do not include the physical conditions needed
to estimate link range or measurement error in the installed sensors.

Figure 4 shows the interface and the reference used during one of the turbidity adjustments, whose

values were entered into the calibration table and subsequently reproduced by the system.

Figur
e 4. Record of one of the points used during turbidity adjustment
Not
e. The interface shows the adjusted value, and the DR/890 displays the reference used during calibration. The numerical
agreement corresponds to an adjustment point; the instrument reports FAU, while the application identifies the variable in

NTU. In this scr
eenshot, the interface retains the SEN0189 label, although the sensor used was the TS-300B. Source: Own
work.

This agreement describes the adjustment of the conversion at the recorded points. Table 3 specifies the

scope of the turbidity, flow
-rate, and temperature checks, including the distinction between a calibration
reference and an independent comparison.
pág. 5085
Tabl
e 3. Scope of the complementary variable checks
Variable
Reference or
procedure
Documented result Scope
Turbidity

Two adjustment

points using the

DR/890

Numerical values of

88 and 377

reproduced after

adjustment

Adjustment
-point
check; no independent

validation or

demonstrated

FAU/NTU

equivalence

Estimated
flow rate

Visual

comparison with

the level
–flow
scale

420 LPS displayed;

observed level

between the 400 and

500 LPS marks,

nearer 400

Approximate

operational

agreement; error not

quantified

Temperature

Acquisition,
transmission,
and
visualization

Reading displayed by

the system

Functional check

without an

independent reference

Not
e. Photographs of the instrument and interface are available for the turbidity point corresponding to 88. The point
corresponding to 377 was documented during the same adjustment session and has an interface record. Source: Own work.

The DR/890 instrument reports turbidity in FAU, while the application identifies the variable in NTU,

so numerical agreement between their displays does not establish metrological equivalence. According

to the Centro Español de Metrología (n.d.), calibrati
on must be distinguished from adjustment because
it relates instrument indications to suitable measurement standards and their uncertainties. This check

examined the reproduction of the points entered into the table; assessing accuracy would require a

comp
atible procedure, traceable references, and observations different from those used to adjust the
conversion.

After the calibrations were applied, the graphs showed segments without wide fluctuations during the

visible intervals, a behavior described as short
-term visual stability because no series of observations
was collected under a defined procedure to estimat
e repeatability. The consistency of the output must
also be considered alongside the water conditions and the processing applied, as it does not establish

measurement precision on its own.

DISCUSSION

The systems developed by Silva Torres and Coello Hurtado (2020) and Jabbar et al.
(2024) use gateways
and connected platforms for water monitoring, while Pires and Gomes (2024) also include local
pág. 5086
processing and Node-RED visualization.
The present proposal shares local processing with the latter
work, using a desktop application linked to MariaDB to bring together reception, conversion, storage,

and data access. The analysis focuses on integrating these functions with the independent tra
nsmission
of variables and on the mounting conditions observed during the temporary installation.

The comparison with Forhad et al.
(2024) identifies a different implementation scope, as their
architecture incorporates instrumentation, a programmable logic controller, and cloud services,
compared with the ESP32 node and Raspberry Pi station examined here.
These differences reflect
design decisions for different needs; the available results do not establish economic superiority,

equivalent measurement accuracy, or better performance relative to those systems.

The study documents the integration of multiparameter acquisition, independent messages, and local

processing through a point
-to-point LoRa link, including a mounting difficulty that directly affected
reception during installation. Distinguishing message a
rrival from interface updates and persistence also
clarifies the data path and avoids assigning the same operating interval to services that function

differently.

Kabi et al. (2023) examined communication through RSSI and SNR records from different locations,
also considering receiver height.
Their procedure provides a reference for extending the evaluation of
this prototype, whose documented tests focused on functional integration. Studying link performance

would require simultaneous transmission and reception records, sequence identification,
and
measurements of signal conditions over defined periods, followed by repeated checks at other distances

and with differen
t configurations.
CONCLUSIONS

The developed architecture integrated multiparameter acquisition with reception and local processing

through a point
-to-point LoRa link, while the documented executions verified variable identification
and the path followed by readings through storage and
retrieval. These results correspond to the
functional scope established for the prototype and the installation conditions examined.

The preliminary check and temporary installation provided observations at two approximate

separations, without constituting a comparative evaluation of performance by distance. During the

temporary installation, reception was restored after the antenna mou
nting was modified, showing that
pág. 5087
the physical arrangement of components must be checked together with the software and connections,

particularly when the enclosure and the path between nodes form part of the operating conditions.

Independent transmission of each variable allowed received messages to be processed when a sequence

remained incomplete, although the absence of sequence numbers and acknowledgments prevented total

packet loss from being reconstructed. Adding these records
, together with RSSI, SNR, and latency
measurements over defined periods, would allow a more detailed evaluation of the link and help

distinguish transmission omissions from reception failures.

The calibration checks documented the conversion of readings and the reproduction of adjustment

points, while the visual stability of the graphs and operational assessments complemented the functional

review without establishing metrological accuracy. Appl
ying the architecture in similar environments
requires the link mounting and configuration to be examined and the calibration relationships to be

defined according to the conditions of each installation.

BIBLIOGRAPHIC REFERENCES

Baltuille, P. (2023, June 15). LoRaWAN y su aportación a las tecnologías IIoT. Instituto Nacional de
Ciberseguridad.
https://www.incibe.es/incibe-cert/blog/lorawan-y-su-aportacion-las-
tecnologias-iiot

Centro Español de Metrología. (n.d.). ¿Qué diferencia existe entre calibración y verificación?

https://www.cem.es/es/divulgacion/preguntas-frecuentes/diferencia-existe-entre-calibracion-

verificacion

Forhad, H. M., Uddin, M. R., Chakrovorty, R. S., Ruhul, A. M., Faruk, H. M., Kamruzzaman, S., . . .

Morshed, A. K. M. M. (2024).
IoT based real-time water quality monitoring system in water
treatment plants (WTPs).
Heliyon, 10(23), e40746.
https://doi.org/10.1016/j.heliyon.2024.e40746

Jabbar, W. A., Ting, T. M., Hamidun, M. F. I., Kamarudin, A. H. C., Wu, W., Sultan, J., . . .
Ali, M. A.
H. (2024).
Development of LoRaWAN-based IoT system for water quality monitoring in rural
areas.
Expert Systems with Applications, 242, 122862.
https://doi.org/10.1016/j.eswa.2023.122862

Kabi, J. N., wa Maina, C., Mharakurwa, E. T., & Mathenge, S. W. (2023). Low cost, LoRa based river
pág. 5088
water level data acquisition system.
HardwareX, 14, e00414.
https://doi.org/10.1016/j.ohx.2023.e00414

Pires, L. M., & Gomes, J. (2024). River water quality monitoring using LoRa
-based IoT. Designs, 8(6),
127.
https://doi.org/10.3390/designs8060127
Schwaber, K., & Sutherland, J. (2020). La guía de Scrum: La guía definitiva de Scrum: Las reglas del
juego.
https://scrumguides.org/docs/scrumguide/v2020/2020-Scrum-Guide-Spanish-Latin-
South-American.pdf

Silva Torres, D. A., & Coello Hurtado, J. I. (2020). Diseño e implementación de un sistema de
monitoreo en tiempo real de sensores de temperatura, turbidez, TDS y pH para la calidad del
agua utilizando la tecnología LoRaWAN [Degree project, Universidad Politécnica Salesiana].
Repositorio Institucional de la Universidad Politécnica Salesiana.

https://dspace.ups.edu.ec/handle/123456789/19627